The static-analysis CI job runs 'staticcheck ./...' directly.
Standalone staticcheck uses //lint:ignore directives, not the
//nolint comments that golangci-lint reads.
SA1008 (non-canonical header key) on three ETag lines:
handlers_etag_test.go:228, :270
mac_mapping_integration_test.go:226
ETag must stay non-canonical — Bose speakers reject 'Etag'.
Existing //nolint:canonicalheader / //nolint:staticcheck comments
remain for golangci-lint; //lint:ignore SA1008 is added for the
standalone staticcheck invocation.
U1000 (unused function) on writeBMXUnauthorized in handlers_bmx.go:
The auth gate is temporarily disabled; the helper is kept as a
restore point. //lint:ignore U1000 replaces //nolint:unused because
golangci-lint's staticcheck runner also honours //lint:ignore,
making //nolint:unused redundant (nolintlint would complain).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Mirrors the .md/.txt sweep across all tracked _test.go, testdata XML,
and .http integration files. Test files are self-contained (producer
+ assertion in the same file), so the matched-pair swap stays green
under `go test ./...`.
Mapping applied:
192.168.178.[0-9]+ → 192.0.2.[same]
192.168.1.[0-9]+ → 192.0.2.[same]
Sound Machinechen → Living Room SoundTouch
A Sound Machine → Kitchen SoundTouch
A81B6A536A98 + case/separator variants → AABBCCDDEEFF (etc.)
A81B6A849D99 → AABBCCDDEE01
A81B6A849D88 → AABBCCDDEE03
A81B6A536A09 → AABBCCDDEE04
884AEAEEBD27 → AABBCCDDEE02
3230304 → 1000001
9569497 → 1000002
Two semantic fixes alongside the bulk swap:
- pkg/service/zeroconf/zeroconf_test.go: the "private 192" and
"strips query" cases pin acceptance of RFC-1918 192.168/16. They
must use a real 192.168 value; doc-range IPs would (correctly) be
rejected by validateZcBaseURL. Switched to 192.168.10.10 — generic
enough not to match any home LAN default, real enough for the
validator. Added a comment explaining why this single test still
carries a 192.168 literal.
- pkg/service/setup/setup_test.go: TestTestDNSRedirection mocks the
device's `od -An -tu1` byte output, which is space-separated
octets ("192 168 1 100"). My sed only matched the dot-separated
form, so the mock was returning the old IP while the test
assertions had moved to the doc range. Updated to " 192 0 2 100".
go build ./... clean. go test ./... clean (only TestDocsConsistency
remains failing, which is a pre-existing/untracked-file issue).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
feat: improve Bose SoundTouch parity, Spotify integration, and data
reliability
- Update XML marshaling for ServicePreset and ServiceRecent to match
Bose parity requirements.
- Add support for adding music sources via
`/streaming/account/{account}/source`.
- Implement HandleBoseAccountToken for Spotify OAuth code exchange and
token persistence.
- Implement atomic file writes in the datastore to prevent data
corruption.
- Add startup logic to initialize default sources for existing devices.
- Expand test coverage with new parity regression and Spotify
integration tests.
---------
Co-authored-by: Junie <junie@jetbrains.com>
Co-authored-by: Copilot Autofix powered by AI <62310815+github-advanced-security[bot]@users.noreply.github.com>
- Enhance initial and full data synchronization to better align with
upstream services.
- Update data structures in 'pkg/models' to support missing fields
(e.g., SecretType for Spotify).
- Improve 'datastore' persistence logic for presets, recents, and
sources.
- Add comprehensive regression tests for sync and datastore operations.
- Update documentation on parity status and improvements.
Co-authored-by: Junie <junie@jetbrains.com>
Co-authored-by: Junie <junie@jetbrains.com>
- Replace serial number-based directory structure with deviceId from device /info
- Extract migration logic to handle transition from old to new directory structure
- Fix directory resolution bug that prevented proper migration to deviceId-based paths
- Ensure all device data (Presets.xml, Sources.xml, Recents.xml) preserved during transition
- Add configurable migration with --migration-enabled and --migration-dry-run flags
- Update DeviceInfo.xml to reflect authoritative deviceId from device's /info endpoint
- Directory structure now: /devices/{deviceId}/ instead of /devices/{serialNumber}/
This aligns the directory structure with the device's self-declared identity
and ensures data consistency with the device's /info endpoint.
Enhances device identification by adding MAC address normalization and comprehensive documentation.
- Add `MAC-ADDRESS-MAPPING.md` guide explaining device identification and troubleshooting.
- Implement `normalizeMAC` in `DataStore` to handle various MAC formats (case-insensitive, with/without separators).
- Export `EnrichDeviceInfo` in UPnP discovery to allow better integration and testing.
- Update `TROUBLESHOOTING.md` with a new section on device identification issues.
- Add comprehensive integration and diagnostic tests for MAC mapping, case sensitivity, and UPnP discovery.
- Update documentation structure (`README.md`, `SUMMARY.md`) to include the new mapping guide.