Mirrors the .md/.txt sweep across all tracked _test.go, testdata XML,
and .http integration files. Test files are self-contained (producer
+ assertion in the same file), so the matched-pair swap stays green
under `go test ./...`.
Mapping applied:
192.168.178.[0-9]+ → 192.0.2.[same]
192.168.1.[0-9]+ → 192.0.2.[same]
Sound Machinechen → Living Room SoundTouch
A Sound Machine → Kitchen SoundTouch
A81B6A536A98 + case/separator variants → AABBCCDDEEFF (etc.)
A81B6A849D99 → AABBCCDDEE01
A81B6A849D88 → AABBCCDDEE03
A81B6A536A09 → AABBCCDDEE04
884AEAEEBD27 → AABBCCDDEE02
3230304 → 1000001
9569497 → 1000002
Two semantic fixes alongside the bulk swap:
- pkg/service/zeroconf/zeroconf_test.go: the "private 192" and
"strips query" cases pin acceptance of RFC-1918 192.168/16. They
must use a real 192.168 value; doc-range IPs would (correctly) be
rejected by validateZcBaseURL. Switched to 192.168.10.10 — generic
enough not to match any home LAN default, real enough for the
validator. Added a comment explaining why this single test still
carries a 192.168 literal.
- pkg/service/setup/setup_test.go: TestTestDNSRedirection mocks the
device's `od -An -tu1` byte output, which is space-separated
octets ("192 168 1 100"). My sed only matched the dot-separated
form, so the mock was returning the old IP while the test
assertions had moved to the doc range. Updated to " 192 0 2 100".
go build ./... clean. go test ./... clean (only TestDocsConsistency
remains failing, which is a pre-existing/untracked-file issue).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Add `soundtouch-cli setup` subcommand group covering the full reset →
re-provision → pair lifecycle as a scriptable alternative to the web UI:
inspect, verify, plan, factory-reset, wait-ap, wifi-push, wait-online,
ssh-check, install-ca, migrate, reboot, pair (bare | full state machine)
Supporting library code lives in pkg/service/setup: factory_reset.go,
wifi_provision.go, inspect.go, init_plan.go, setup_session.go.
Confirmed against ST10 firmware 27.0.6 that bare setMargeAccount over
WebSocket — no SETUP_START/SETUP_ENTER/SETUP_LEAVE bracket — is
sufficient to pair a factory-reset speaker; the firmware materializes
SystemConfigurationDB.xml and Sources.xml itself and the pairing
survives reboot. Result and field-by-field SystemConfigurationDB
comparison documented in docs/analysis/SETUP-WEBSOCKET-EXPERIMENT.md.
Captures the device's pre-reset DELETE-to-marge plus its LAN peer
notification flow in docs/analysis/FACTORY-RESET-PROTOCOL.md.
Perf: batch GetMigrationSummary's SSH probes into one Run() call via
ssh_probe.go / ssh_probe_apply.go — was ~8 sequential dials at
500-1000 ms each on FW 27 crypto, now one round-trip. Same data shape,
same MigrationSummary fields populated.
Fixes /clockTime and /clockDisplay wire formats — firmware 27 rejects
the legacy flat XML ("Error parsing request"). ClockTimeRequest now
uses utcTime attribute; ClockDisplayRequest emits the nested
<clockConfig> envelope with timezoneInfo/timeFormat/brightnessLevel.
Removes cmd/example-init-speaker (superseded by setup pair).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Fixed nil pointer dereference warnings by using t.Fatal instead of t.Error
- In unified_test.go: Changed service nil check to use t.Fatal
- In clockdisplay_test.go: Changed request nil check to use t.Fatal
Using t.Fatal ensures test execution stops if pointer is nil,
eliminating possibility of subsequent nil pointer dereference.
Progress: Eliminated all 5 staticcheck issues
Total issues: 21 → 16 (24% improvement)
Remaining:
- gocyclo: 14 (complexity - requires refactoring)
- revive: 1 (DiscoveryService naming)
- unparam: 1 (client.post result parameter)
- Implement GET/POST /clockTime endpoints for device time management
- Implement GET/POST /clockDisplay endpoints for clock display configuration
- Implement GET /networkInfo endpoint with real API structure
- Add comprehensive models for ClockTime, ClockDisplay, and NetworkInformation
- Update NetworkInformation to match real SoundTouch API responses:
* WiFi interfaces with SSID, frequency, signal strength, and connection state
* Ethernet interfaces with connection state
* Proper attribute-based XML structure matching actual device responses
- Add CLI support for all system endpoints with detailed output formatting
- Add comprehensive test coverage for all new models and client methods
- Update documentation to reflect real API structure and capabilities
- Anonymize all personal data (IP addresses, device IDs, device names)
- Add SYSTEM-ENDPOINTS.md documentation with real-world examples
Features:
- Clock time sync with current system time or specific timestamps
- Clock display configuration (enable/disable, format, brightness, auto-dim)
- Rich network interface information with WiFi signal quality and frequency bands
- Support for both WiFi and Ethernet SoundTouch devices
- Validated against real SoundTouch 10 and SoundTouch 20 device responses
All tests pass and builds successfully.